Continental Disc Corporation has been an excellent OEM partner and we look forward to continuing to meet end-user needs together. “The addition of the Texas Gulf Coast Region to our existing exclusive distribution territory of Continental Disc gives us the ability to serve our customers across our entire footprint with a top-tier brand.

first floating foundation in kilgore tx

Setpoint Integrated Solutions brings a vast array of both commercial and technical support. Setpoint IS has and continues to be a value added business partner for the CDC and Groth product lines in the North TX ( Kilgore, TX ), Louisiana, Arkansas, Western TN and Mississippi Territories. locations in Port Arthur, La Porte, Richwood, and Corpus Christi TX. These offices consist of the Setpoint I.S. will acquire the sole exclusive Representative contract for Continental Rupture Discs for the Texas Gulf Coast Region. 19, 2018) – Setpoint Integrated Solutions (Setpoint I.S.) is pleased to announce that effective midnight Feb. Setpoint Integrated Solutions expands territory agreement with Continental Disc Corporation (CDC). Product Manager, Consolidated Valves, Baker Hughes, a GE company The limit washer is cut to the appropriate length based on the lift required.Ĭontact Setpoint Integrated Solutions, 1-80 for all of your relief valve needs from Service to New Assembly. Lift restriction is accomplished by installing a limit washer between the guide and disc holder as shown in the figure.

First floating foundation in kilgore tx code#

The valve configuration code will have an “RL” included at the end. SRVSpeQ has the restricted lift option included and requires the percentage restriction to be inputted. Note that valves restricted under a VR repair will have the rated restricted capacity and the restricted lift value listed on the repair nameplate. Prior to making a final selection the purchaser shall confirm that the restricted lift relief device meets the design requirements. The manufacturer shall determine the lift that will provide a restricted rated capacity that meets the required capacity.

first floating foundation in kilgore tx

The nameplate on restricted lift relief devices shall be stamped to identify the reduced lift value and the rated capacity based on that reduced lift value.Restricted lift pressure relief valves may be specified by providing the manufacturer with a required restricted capacity. Paragraph UG-136(c)(4)(b)(5) gives the requirements that an ASME Assembler must meet to supply restricted lift valves.Ī VR stamp holder is not required by NB-23 (NBIC Part 3) to have ASME restricted lift capacity certification when performing lift restriction as part of a repair.

First floating foundation in kilgore tx full#

Paragraph UG-133(h) states that when sizing and selecting valves, the restricted lift nameplate capacity shall be determined by multiplying the capacity at full rated lift as defines in UG-131(e)(3) by the ratio of the restricted lift to the full rated lift. This option is available for all compressible media (gases and steam) applications for both new valves and repair valves.ĪSME B&PVC Section VIII, paragraph UG-136(a)(11) gives the requirements that must be met for restricted lift applications which states valves shall not have their lifts restricted to a value less than 30% of full rated lift, or 0.080 in. This certification was granted by compliance to ASME B&PVC Section VIII, paragraph UG-131(e)(1).

First floating foundation in kilgore tx series#

API 520 Part 2, Sixth Edition, paragraph 7.3.7.5 also recommends restricting the valve lift to address high inlet pressure losses.Ĭonsolidated offers the 1900 Series API 526 pressure relief valve with a restricted lift option for orifices F-W under National Board capacity certification number 18223. A lower rated capacity, based on the reduced lift, will lower the inlet and outlet piping pressure losses and reduce the acoustic effects. A restricted lift pressure relief valve has a reduced flow area (reduced effective orifice area), resulting in a lower rated capacity for the valve. This reduction in rated capacity can be achieved by restricting the lift. In some applications, the user may require an orifice somewhere in between so that the resulting rated capacity is lower. Do you have pressure relief valves with inlet pressure losses greater than 3% of the valve set pressure? Do you have over sized pressure relief valves causing valve chatter? Did you know a restricted lift pressure relief valve could solve these common problems?ĪPI 526 Table 1 shows a 21% to 78% increase in effective orifice area from one selected orifice to the next lettered orifice.